Expert calibration lab in
Tananger – Norway

Opening hours

Mon
07:30 - 15:30
Tue
07:30 - 15:30
Wed
07:30 - 15:30
Thu
07:30 - 15:30
Fri
07:30 - 15:30
Contact
+47 51 71 95 00
NorSea Base, Bygg 53
4056 Tananger
Norway

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Dimensional
Electricity
Humidity
Force
Temperature
Mass / Scale
Torque
Pressure / Vacuum
Volume
Dimensional

Dimensional

Accredited Capabilities

Global Calibration Scope

  • Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
  • Long length (standard tape rules, peripheral gauges…): up to 100 m

Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Accredited Capabilities

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Humidity

Non-accredited Capabilities

Our laboratory calibrates humidity sensors between 10-90 % RH at 20±2°C

Force

Force

Non-accredited Capabilities

Compression: up to 1 MN

Tension: up to 125 kN

Temperature

Temperature

Accredited Capabilities

Our laboratory in Tananger calibrates most temperature measurement systems. Our range is -196 to 660°C.

ITS-90 fixed point references

  • Ice: 0.01 ° C Triple point for water
  • Gallium: 29.7646 ° C
  • Zinc: 419.527 ° C
  • Aluminum: 660,323 ° C
Mass / Scale

Mass / Scale

Accredited Capabilities
  • Accredited calibration of masses (weights/load) at our laboratory in Tananger
    • Measuring range: 100 mg – 20 kg
    • CMC from 0.26 mg
  • Accredited calibration of scales/balances by customer
    • Measuring range: 100 mg – 60 kg
    • CMC from 0.16 mg
  • Traceable calibration of scales/balances up to 2000 kg
  • Traceable calibration of masses (weights) up to 60 kg
Torque

Torque

Non-accredited Capabilities

Our Laboratory in Tananger calibrates torque wrenches from 0 – 1500 Nm

Pressure / Vacuum

Pressure / Vacuum

Accredited Capabilities
  • We cover the pressure range from absolute vacuum to 5000 bar.
  • Traceability to LNE, DHI, RISE and Justervesenet
  • Our best uncertainty is 30 ppm
  • We calibrate differential pressure with up to 400 bar line pressure and 5 bar differential pressure.
Volume

Volume

Non-accredited Capabilities

Global Calibration Scope

  • Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
  • Pipette: 0.1µL up to 1 000 mL
  • Syringe: up to 200 mL

Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional
Electricity
Humidity

Our laboratory calibrates humidity sensors between 10-90 % RH at 20±2°C

Force

Compression: up to 1 MN

Tension: up to 125 kN

Temperature

Our laboratory in Tananger calibrates most temperature measurement systems. Our range is -196 to 660°C.

ITS-90 fixed point references

  • Ice: 0.01 ° C Triple point for water
  • Gallium: 29.7646 ° C
  • Zinc: 419.527 ° C
  • Aluminum: 660,323 ° C
Mass / Scale
  • Accredited calibration of masses (weights/load) at our laboratory in Tananger
    • Measuring range: 100 mg – 20 kg
    • CMC from 0.26 mg
  • Accredited calibration of scales/balances by customer
    • Measuring range: 100 mg – 60 kg
    • CMC from 0.16 mg
  • Traceable calibration of scales/balances up to 2000 kg
  • Traceable calibration of masses (weights) up to 60 kg
Torque

Our Laboratory in Tananger calibrates torque wrenches from 0 – 1500 Nm

Pressure / Vacuum
  • We cover the pressure range from absolute vacuum to 5000 bar.
  • Traceability to LNE, DHI, RISE and Justervesenet
  • Our best uncertainty is 30 ppm
  • We calibrate differential pressure with up to 400 bar line pressure and 5 bar differential pressure.
Volume