CAPABILITIES
Dimensional
Global Calibration Scope
- Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
- Long length (standard tape rules, peripheral gauges…): up to 100 m
Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Electricity
Global Calibration Scope
- AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
- High voltage:
- DC: 1 kV to 200 kV
- AC (50 Hz): 1 kV to 175 kV
- Magnetometers: 0 to 1700 mT…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Humidity
Our laboratory calibrates humidity sensors between 10-90 % RH at 20±2°C
Force
Compression: up to 1 MN
Tension: up to 125 kN
Temperature
Our laboratory in Tananger calibrates most temperature measurement systems. Our range is -196 to 660°C.
ITS-90 fixed point references
- Ice: 0.01 ° C Triple point for water
- Gallium: 29.7646 ° C
- Zinc: 419.527 ° C
- Aluminum: 660,323 ° C
Mass / Scale
- Accredited calibration of masses (weights/load) at our laboratory in Tananger
- Measuring range: 100 mg – 20 kg
- CMC from 0.26 mg
- Accredited calibration of scales/balances by customer
- Measuring range: 100 mg – 60 kg
- CMC from 0.16 mg
- Traceable calibration of scales/balances up to 2000 kg
- Traceable calibration of masses (weights) up to 60 kg
Torque
Our Laboratory in Tananger calibrates torque wrenches from 0 – 1500 Nm
Pressure / Vacuum
- We cover the pressure range from absolute vacuum to 5000 bar.
- Traceability to LNE, DHI, RISE and Justervesenet
- Our best uncertainty is 30 ppm
- We calibrate differential pressure with up to 400 bar line pressure and 5 bar differential pressure.
Volume
Global Calibration Scope
- Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
- Pipette: 0.1µL up to 1 000 mL
- Syringe: up to 200 mL
Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Our laboratory calibrates humidity sensors between 10-90 % RH at 20±2°C
Compression: up to 1 MN
Tension: up to 125 kN
Our laboratory in Tananger calibrates most temperature measurement systems. Our range is -196 to 660°C.
ITS-90 fixed point references
- Ice: 0.01 ° C Triple point for water
- Gallium: 29.7646 ° C
- Zinc: 419.527 ° C
- Aluminum: 660,323 ° C
- Accredited calibration of masses (weights/load) at our laboratory in Tananger
- Measuring range: 100 mg – 20 kg
- CMC from 0.26 mg
- Accredited calibration of scales/balances by customer
- Measuring range: 100 mg – 60 kg
- CMC from 0.16 mg
- Traceable calibration of scales/balances up to 2000 kg
- Traceable calibration of masses (weights) up to 60 kg
Our Laboratory in Tananger calibrates torque wrenches from 0 – 1500 Nm
- We cover the pressure range from absolute vacuum to 5000 bar.
- Traceability to LNE, DHI, RISE and Justervesenet
- Our best uncertainty is 30 ppm
- We calibrate differential pressure with up to 400 bar line pressure and 5 bar differential pressure.