Expert calibration lab in
Recife – Brazil

Opening hours

Mon
08:00 - 17:00
Tue
08:00 - 17:00
Wed
08:00 - 17:00
Thu
08:00 - 17:00
Fri
08:00 - 16:30
Contact
+55 (81) 2137-6100
Ana Maria Vieira, 11
Prazeres
Jaboatão dos Guararapes-PE
CEP: 54325-622
Brasil

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Humidity
Liquid flow
Mass / Scale
Temperature
Volume
Thermal and climatic testing
Torque
Dimensional
Pressure / Vacuum
Electricity
Humidity

Humidity

Accredited Capabilities

Global Calibration Scope

  • Dew Point sensors ranging -90° C to +95° C
  • RH from 0% – 100%

Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Liquid flow

Liquid flow

Accredited Capabilities

Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min

Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Accredited Capabilities

Global Calibration Scope

  • Mass: 1 mg to 1000 kg (range depending to class less than E2, F2, M1…)
  • Scale: 1mg to 200 000 kg with weights class from E2, F1 to M1-2
  • Legal metrology: maintenance and repair for scales up to 180 000 kg

Common equipment serviced: Weight, Weighing devices (Weighing scale, Hopper scale, Tank scale, Platform scale, etc), Weighing instruments for blood collection bags

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Temperature

Accredited Capabilities

Global Calibration Scope

  • Range: -196°C up to 1550°C
  • Fixed points: TP Ar, TP Mercury, TP Water, Melting point of Galium, FP Indium, FP Tin, FP Zinc, FP Al, FP Ag…

Common equipment serviced: temperature measurers, Generators/calibrators, Chillers, Thermistors, Infrared radiation sources, Temperature Controllers, Temperature Indicators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Volume

Volume

Accredited Capabilities

Global Calibration Scope

  • Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
  • Pipette: 0.1µL up to 1 000 mL
  • Syringe: up to 200 mL

Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Thermal and climatic testing

Thermal and climatic testing

Accredited Capabilities

Global Scope

  • 3 to 98 %RH
  • -100 to 1250°C

Common equipment serviced: Climatic chamber, Thermostatic chamber, Refrigerator, Freezer, Oven, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Torque

Accredited Capabilities

Global Calibration Scope

  • Torque measuring devices (sensors, transducers, measuring chains…): 0,001 to 5 000 Nm
  • Hand torque tools (wrenches, screwdrivers …): 0,02 to 5 000 Nm
  • Torque multiplier: 50 to 5 000 Nm

Common equipment serviced: Torque analyzer, Torque sensor, Torque tester, Torquemeter, Torque transducer, Torque multiplier, Torque gun, Torque wrench, Torque screwdriver, Joint simulator, Hydraulic torque wrench

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Accredited Capabilities

Global Calibration Scope

  • Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
  • Long length (standard tape rules, peripheral gauges…): up to 100 m

Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Accredited Capabilities

Global Calibration Scope

  • Vacuum: primary and secondary
  • Altimeter: up to 47 000 m
  • Pressure gauge: up to 500 MPa

Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Accredited Capabilities

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity
Liquid flow
Mass / Scale
Temperature
Volume
Thermal and climatic testing
Torque
Dimensional
Pressure / Vacuum
Electricity

Laboratory tour

Our laboratories provides instrument calibration and repair services that are accredited and/or certified in accordance with ISO/IEC 17025. Instrument calibration and repair services can be delivered at your site or at our lab.