Electricity
Global Calibration Scope
- AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
- High voltage:
- DC: 1 kV to 200 kV
- AC (50 Hz): 1 kV to 175 kV
- Magnetometers: 0 to 1700 mT…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Time / Frequency
Global Calibration Scope
- Tachometer, stroboscope: 1 up to 600 000 RPM
- Frequency meters, frequency generators, counters: up to 40 GHz
Common equipment serviced: Digital Timers, Frequency Counters, Frequency Meters / Generators, Frequency Standards, Stopwatches, Stroboscopes, Tachometers, Timers, Phasemeter, Standard RPM generators, Synchro-resolvers, Signal generators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Global Calibration Scope
- Vacuum: primary and secondary
- Altimeter: up to 47 000 m
- Pressure gauge: up to 500 MPa
Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Torque
Global Calibration Scope
- Torque measuring devices (sensors, transducers, measuring chains…): 0,001 to 5 000 Nm
- Hand torque tools (wrenches, screwdrivers …): 0,02 to 5 000 Nm
- Torque multiplier: 50 to 5 000 Nm
Common equipment serviced: Torque analyzer, Torque sensor, Torque tester, Torquemeter, Torque transducer, Torque multiplier, Torque gun, Torque wrench, Torque screwdriver, Joint simulator, Hydraulic torque wrench
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Accelerometry
Global Calibration Scope
- Shock: between 20g and 5,000g (subject to device weight and voltage output)
- Accelerometer: 0.1 m/s² to 750 m/s² (0.4 Hz to 10 kHz…)
Common equipment serviced: Integrated piezoelectric electronics, Piezoelectric accelerometers, Piezoresistive accelerometers, Charge amplifiers and systems
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Temperature
Global Calibration Scope
- Range: -196°C up to 1550°C
- Fixed points: TP Ar, TP Mercury, TP Water, Melting point of Galium, FP Indium, FP Tin, FP Zinc, FP Al, FP Ag…
Common equipment serviced: temperature measurers, Generators/calibrators, Chillers, Thermistors, Infrared radiation sources, Temperature Controllers, Temperature Indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Humidity
Global Calibration Scope
- Dew Point sensors ranging -90° C to +95° C
- RH from 0% – 100%
Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.