Expert calibration lab in
Cincinnati, Ohio

Opening hours

Mon
08:00 - 05:00
Tue
08:00 - 05:00
Wed
08:00 - 05:00
Thu
08:00 - 05:00
Fri
08:00 - 05:00
Contact
(513) 874-2122
253 Circle Freeway Drive
Cincinnati, OH 45246

ACCREDITATIONS

ISO/IEC 17025 via A2LA

Scope of accreditation
A2LA Cert #1570.01

A2LA Cert #1570.01

ISO 17025

ISO 17025

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Dimensional
Time / Frequency
Chemical
Electricity
Force
Humidity
Pressure / Vacuum
Mass / Scale
Temperature
Torque
Hardness
Dimensional

Dimensional

Accredited Capabilities

Global Calibration Scope

  • Gauge blocks: -up to 20”
  • Ring gauges: -up to 20”
  • Thread plugs: -up to 12”
  • Tapers: -up to 8”
  • Plug gauges: -up to 11”
  • Length standards: -up to 72”
  • Squares: -up to 18”
  • Thread rings: Up to 7.8”
  • Surface plates: Up to 180”

Common equipment serviced: Gauge blocks, Thread rings, Thread plugs, Plain rings, Plain plugs, Pin gauges, Sand sieve, Length standards, Thread wires, Squares, Surface plates, Angle blocks

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Accredited Capabilities

Global Calibration Scope

  • Timometer 0.039s/day

Common equipment serviced: Stop watches, Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chemical

Chemical

Accredited Capabilities

Global Calibration Scope

  • pH (4,7,10)

Common equipment serviced: pH meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Accredited Capabilities

Global Calibration Scope

  • High voltage measure: -up to 60kVdc/42kVac
  • DC current: -up to 1000A w/ coil
  • Phase: 10 to 30khz, up to 10°
  • Oscilloscopes: -up to 1.1GHz

Common equipment serviced: Power supplies, LCR meters, Electronic loads, Multimeters, Clamp meters, Oscilloscopes, Shunts, Process calibrators, Hypots, Ohmmeters, Power quality, Thermometers-simulate

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Accredited Capabilities

Global Calibration Scope

  • Up to 500lbs

Common equipment serviced: Load cells, Force gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Humidity

Accredited Capabilities

Global Calibration Scope

  • 3 to 95% HR from 15 °C to 60 °C with humidity generator  and chilled mirror

Common equipment serviced: Hygrometers, Humidity sensor, Temp humidity meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Accredited Capabilities

Global Calibration Scope

  • Pneumatic: -14.2 to 1000PSIG
  • Hydraulic: 0 to 10000PSI

Common equipment serviced: Pressure gauges, Pressure indicators, Pressure transducers, Vacuum gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Accredited Capabilities

Global Calibration Scope

  • Balances: -up to 2kg
  • Scales: -up to 2000lbs

Common equipment serviced: Scales, Balances

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Temperature

Accredited Capabilities

Global Calibration Scope

  • Teperature measure: from –38 to 420°C

Common equipment serviced: Ovens, Temp humidity meters, Environmental chambers, Furnaces, Baths, Drywells, Thermocouples, Temperature probes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Torque

Accredited Capabilities

Global Calibration Scope

  • Torque wrenches: -up to 1000ft-lbs
  • Torque transducers and torque meters: -up to 500lbs

Common equipment serviced: Torque wrenches, Torque drivers, Torque transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hardness

Hardness

Accredited Capabilities

Global Calibration Scope

  • Indirect HRA, HRC, HRBW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW

Common equipment serviced: Rockwell Hardness Testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Global Calibration Scope

  • Gauge blocks: -up to 20”
  • Ring gauges: -up to 20”
  • Thread plugs: -up to 12”
  • Tapers: -up to 8”
  • Plug gauges: -up to 11”
  • Length standards: -up to 72”
  • Squares: -up to 18”
  • Thread rings: Up to 7.8”
  • Surface plates: Up to 180”

Common equipment serviced: Gauge blocks, Thread rings, Thread plugs, Plain rings, Plain plugs, Pin gauges, Sand sieve, Length standards, Thread wires, Squares, Surface plates, Angle blocks

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Global Calibration Scope

  • Timometer 0.039s/day

Common equipment serviced: Stop watches, Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chemical

Global Calibration Scope

  • pH (4,7,10)

Common equipment serviced: pH meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Global Calibration Scope

  • High voltage measure: -up to 60kVdc/42kVac
  • DC current: -up to 1000A w/ coil
  • Phase: 10 to 30khz, up to 10°
  • Oscilloscopes: -up to 1.1GHz

Common equipment serviced: Power supplies, LCR meters, Electronic loads, Multimeters, Clamp meters, Oscilloscopes, Shunts, Process calibrators, Hypots, Ohmmeters, Power quality, Thermometers-simulate

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Global Calibration Scope

  • Up to 500lbs

Common equipment serviced: Load cells, Force gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Global Calibration Scope

  • 3 to 95% HR from 15 °C to 60 °C with humidity generator  and chilled mirror

Common equipment serviced: Hygrometers, Humidity sensor, Temp humidity meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Global Calibration Scope

  • Pneumatic: -14.2 to 1000PSIG
  • Hydraulic: 0 to 10000PSI

Common equipment serviced: Pressure gauges, Pressure indicators, Pressure transducers, Vacuum gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Global Calibration Scope

  • Balances: -up to 2kg
  • Scales: -up to 2000lbs

Common equipment serviced: Scales, Balances

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Global Calibration Scope

  • Teperature measure: from –38 to 420°C

Common equipment serviced: Ovens, Temp humidity meters, Environmental chambers, Furnaces, Baths, Drywells, Thermocouples, Temperature probes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Global Calibration Scope

  • Torque wrenches: -up to 1000ft-lbs
  • Torque transducers and torque meters: -up to 500lbs

Common equipment serviced: Torque wrenches, Torque drivers, Torque transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hardness

Global Calibration Scope

  • Indirect HRA, HRC, HRBW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW

Common equipment serviced: Rockwell Hardness Testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.