Dimensionnel cotes variables
Expert calibration lab in
Bollène – France
Opening hours
Lieu'dit Le Lauzon
84500 BOLLÈNE

CAPABILITIES
Dimensional
Dimensionnel cotes variables
Electricity
Global Calibration Scope
- AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
- High voltage:
- DC: 1 kV to 200 kV
- AC (50 Hz): 1 kV to 175 kV
- Magnetometers: 0 to 1700 mT…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Force
Capteurs de force, Dynamomètres, Pesons, Balances de pesée…
- Génération de force (traction/compression) avec machine d’essai (200 kN): pinces à sertir, tensiomètres de câble…
- Machines d’essais mécaniques sur site sous accréditation COFRAC 1-6656 portée par Trescal Bordeaux :
- Machines de dureté,
- Mouton-pendules,
- Extensomètres,
- Machines de traction/compression (matériaux béton ou métallique) : 3 000 kN
Gas flow
Débitmètres Argon sur site
Liquid flow
Débitmètres liquide à ultrasons
Pressure / Vacuum
Manomètres, Jauges de vide, Balances manométriques, Générateurs de pression, Soupapes…
- Plages de mesure : 0 à 1 200 bar sous accréditation COFRAC 2-6654 – 0 à 2 500 bar hors accréditation
- Vide secondaire : 1.10-4 mbar à 1.10-3 mbar
- Vide primaire : 1.10-3 mbar à 1 000 mbar
- Jauge « full range » : 1.10-4 mbar à 1 000 mbar
- Compétence unique en France : Soupape de sécurité en air et en eau : 300 bar + test Kellogg
Temperature
Global Calibration Scope
- Range: -196°C up to 1550°C
- Fixed points: TP Ar, TP Mercury, TP Water, Melting point of Galium, FP Indium, FP Tin, FP Zinc, FP Al, FP Ag…
Common equipment serviced: temperature measurers, Generators/calibrators, Chillers, Thermistors, Infrared radiation sources, Temperature Controllers, Temperature Indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Time / Frequency
Global Calibration Scope
- Tachometer, stroboscope: 1 up to 600 000 RPM
- Frequency meters, frequency generators, counters: up to 40 GHz
Common equipment serviced: Digital Timers, Frequency Counters, Frequency Meters / Generators, Frequency Standards, Stopwatches, Stroboscopes, Tachometers, Timers, Phasemeter, Standard RPM generators, Synchro-resolvers, Signal generators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Torque
Serrage au Couple, Serrage Hydraulique ou Pneumatique…
- Clés hydrauliques : 50 000 N.m
- Visseuses : 5 000 N.m
- Clés angulaires : 2 500 N.m
- Multiplicateurs de couple
- Chaînes de mesure de couple, couplemètres sous accréditation COFRAC 2-6655 : 6 000 N.m
Testing machines
Global Scope: Compression/Tensile testing machine up to 2 000 kN (Tensile) and 3 MN (Compression)
Common equipment serviced: Compression/Tensile testing machine
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Thermal and climatic testing
Caractérisation Étuve, Enceinte, Four et Bain suivant les normes FD X15-140 et AMS 2750
Capteurs de force, Dynamomètres, Pesons, Balances de pesée…
- Génération de force (traction/compression) avec machine d’essai (200 kN): pinces à sertir, tensiomètres de câble…
- Machines d’essais mécaniques sur site sous accréditation COFRAC 1-6656 portée par Trescal Bordeaux :
- Machines de dureté,
- Mouton-pendules,
- Extensomètres,
- Machines de traction/compression (matériaux béton ou métallique) : 3 000 kN
Débitmètres Argon sur site
Débitmètres liquide à ultrasons
Manomètres, Jauges de vide, Balances manométriques, Générateurs de pression, Soupapes…
- Plages de mesure : 0 à 1 200 bar sous accréditation COFRAC 2-6654 – 0 à 2 500 bar hors accréditation
- Vide secondaire : 1.10-4 mbar à 1.10-3 mbar
- Vide primaire : 1.10-3 mbar à 1 000 mbar
- Jauge « full range » : 1.10-4 mbar à 1 000 mbar
- Compétence unique en France : Soupape de sécurité en air et en eau : 300 bar + test Kellogg
Serrage au Couple, Serrage Hydraulique ou Pneumatique…
- Clés hydrauliques : 50 000 N.m
- Visseuses : 5 000 N.m
- Clés angulaires : 2 500 N.m
- Multiplicateurs de couple
- Chaînes de mesure de couple, couplemètres sous accréditation COFRAC 2-6655 : 6 000 N.m
Caractérisation Étuve, Enceinte, Four et Bain suivant les normes FD X15-140 et AMS 2750
Réparation-Maintenance : électrique, mécanique (partenariat Hytorc)
- Intervention sur site sur INB, sur l’ensemble des donneurs d’ordres
- Métrologie en Zone Chaude :
- Techniciens Habilités en CAT : B
- CEFRI – E