Expert calibration lab in
Baltimore, Maryland

Opening hours

Mon
08:00 - 05:00
Tue
08:00 - 05:00
Wed
08:00 - 05:00
Thu
08:00 - 05:00
Fri
08:00 - 05:00
Contact
(410) 337-0687
47 Loveton Circle, Suite I
Sparks, MD 21152

ACCREDITATIONS

ISO/IEC 17025

ANSI/NCSL Z540-1

ANSI/NCSL Z540.3

Scope of accreditation
A2LA cert #1346.01

A2LA cert #1346.01

ISO/IEC 17025

ISO/IEC 17025

ANSI/NCSL Z540-1

ANSI/NCSL Z540-1

ANSI/NCSL Z540.3

ANSI/NCSL Z540.3

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Accelerometry
Dimensional
Electricity
Force
Hardness
Humidity
Mass / Scale
Pressure / Vacuum
Temperature
Torque
Time / Frequency
Accelerometry

Accelerometry

Accredited Capabilities

Global Calibration Scope

  • Accelerometer calibration from 5Hz-10kHz

Common equipment serviced: Accelerometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Accredited Capabilities

Global Calibration Scope

  • Gauge blocks: up to 20°
  • Thread plugs: up to 10°
  • Thread and plan plug gauges: up to 10°
  • Thread rings: up to 4°
  • Plan ring: up to 10°

Common equipment serviced: Thread plugs, Thread rings, Plan ring, Plan plug, Pin Gauges, Gauge blocks, NPT thread plugs and rings, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Accredited Capabilities

Global Calibration Scope

  • DC voltage measure: up to 10kV
  • DC voltage generate: up to 1100V
  • DC current measure: up to 300A
  • DC current generate: up to 1025A W/COIL
  • Resistance generate: up to 100GOHM

Common equipment serviced: Power supplies, Hypots, Multimeters, Oscilloscopes, Resistors, Clamp meters, Shunts

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Accredited Capabilities

Global Calibration Scope

  • Up to 120KLBS

Common equipment serviced: Load cells, Force gauges, Hanging dynometers, Crane scales, Aircraft scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hardness

Hardness

Accredited Capabilities

Global Calibration Scope

  • Durometer calibration per ASTM D2240

Common equipment serviced: Durometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Humidity

Accredited Capabilities

Global Calibration Scope

  • 10 to 95% RH

Common equipment serviced: Temperature humidity meters, Temperature humidity probes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Accredited Capabilities

Global Calibration Scope

  • Scales: 0-500lbs
  • Balances: 0-10kg

Common equipment serviced: Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Accredited Capabilities

Global Calibration Scope

  • Hydraulic: up to 10000 PSI
  • Pneumatic: up to 3000PSI

Common equipment serviced: Pressure gauges, Vacuum gauges, Pressure transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Temperature

Accredited Capabilities

Global Calibration Scope

  • Blackbody: -15 to 500°C
  • Temperature measure: -200 to 955°C

Common equipment serviced: Infrared thermometers, RTD sensors, Thermocouples, Temperature probes, Temperature measure, Oven, Furnace, Environmental chamber

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Torque

Accredited Capabilities

Global Calibration Scope

  • Up to 2000 ft-lbs for wrenches and transducers

Common equipment serviced: Torque wrenches, Torque transducers, Torque screwdrivers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Accredited Capabilities

Global Calibration Scope

  • Timometer
  • GPS system

Common equipment serviced: Stopwatches, Times, Frequency counters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Accelerometry

Global Calibration Scope

  • Accelerometer calibration from 5Hz-10kHz

Common equipment serviced: Accelerometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Global Calibration Scope

  • Gauge blocks: up to 20°
  • Thread plugs: up to 10°
  • Thread and plan plug gauges: up to 10°
  • Thread rings: up to 4°
  • Plan ring: up to 10°

Common equipment serviced: Thread plugs, Thread rings, Plan ring, Plan plug, Pin Gauges, Gauge blocks, NPT thread plugs and rings, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Global Calibration Scope

  • DC voltage measure: up to 10kV
  • DC voltage generate: up to 1100V
  • DC current measure: up to 300A
  • DC current generate: up to 1025A W/COIL
  • Resistance generate: up to 100GOHM

Common equipment serviced: Power supplies, Hypots, Multimeters, Oscilloscopes, Resistors, Clamp meters, Shunts

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Global Calibration Scope

  • Up to 120KLBS

Common equipment serviced: Load cells, Force gauges, Hanging dynometers, Crane scales, Aircraft scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Hardness

Global Calibration Scope

  • Durometer calibration per ASTM D2240

Common equipment serviced: Durometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Global Calibration Scope

  • 10 to 95% RH

Common equipment serviced: Temperature humidity meters, Temperature humidity probes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Global Calibration Scope

  • Scales: 0-500lbs
  • Balances: 0-10kg

Common equipment serviced: Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Global Calibration Scope

  • Hydraulic: up to 10000 PSI
  • Pneumatic: up to 3000PSI

Common equipment serviced: Pressure gauges, Vacuum gauges, Pressure transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Global Calibration Scope

  • Blackbody: -15 to 500°C
  • Temperature measure: -200 to 955°C

Common equipment serviced: Infrared thermometers, RTD sensors, Thermocouples, Temperature probes, Temperature measure, Oven, Furnace, Environmental chamber

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Global Calibration Scope

  • Up to 2000 ft-lbs for wrenches and transducers

Common equipment serviced: Torque wrenches, Torque transducers, Torque screwdrivers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Global Calibration Scope

  • Timometer
  • GPS system

Common equipment serviced: Stopwatches, Times, Frequency counters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.